No Logo
Click To Enlarge Image

Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable

(0 reviews)

  • Supplier : Al Yamuna Densons FZE
  • Kit Code : XSOS - 31
  • Standard : IEC-60502-4, IS-13573
  • Cable Size : 1 x 25 - 50 mm2
  • Impulse Voltage Test : 170 kV
  • Availability : In Stock
  • Business Type : Manufacturers

Specifications

Item Code YOZDAD
Brand AL YAMUNA DENSONS
Kit Code XSOS - 31
Standard IEC-60502-4, IS-13573
Cable Size 1 x 25 - 50 mm2
Impulse Voltage Test 170 kV
AC Withstand Test Voltage 86 kV/5 min
Information on technical characteristics, the delivery set, the country of manufacture and the appearance of the goods is for reference only and is based on the latest information available at the time of publications.

Variants

Cable Termination
Item Code #8KRZAU
Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable, 1 x 25 - 50 mm2 , Kit Code XSOS - 31,Standard IEC-60502-4, IS-13573 mm2,Cable Size 1 x 25 - 50 mm2,AC Withstand Test Voltage 86 min,Impulse Voltage Test 170 kV,Brand AL YAMUNA DENSONS

  • Brand:
    AL YAMUNA DENSONS
  • Kit Code:
    XSOS - 31
  • Standard:
    IEC-60502-4, IS-13573
  • Cable Size:
    1 x 25 - 50 mm2
  • Impulse Voltage Test:
    170 kV
  • AC Withstand Test Voltage:
    86 kV/5 min
Cable Termination
Item Code #EKQ6TW
Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable, 1 x 240 - 400 mm2 , Kit Code XSOS - 33,Standard IEC-60502-4, IS-13573 mm2,Cable Size 1 x 240 - 400 mm2,AC Withstand Test Voltage 86 min,Impulse Voltage Test 170 kV,Brand AL YAMUNA DENSONS

  • Brand:
    AL YAMUNA DENSONS
  • Kit Code:
    XSOS - 33
  • Standard:
    IEC-60502-4, IS-13573
  • Cable Size:
    1 x 240 - 400 mm2
  • Impulse Voltage Test:
    170 kV
  • AC Withstand Test Voltage:
    86 kV/5 min
Cable Termination
Item Code #6ZWSNC
Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable, 1 x 500 - 800 mm2 , Kit Code XSOS - 34,Standard IEC-60502-4, IS-13573 mm2,Cable Size 1 x 500 - 800 mm2,AC Withstand Test Voltage 86 min,Impulse Voltage Test 170 kV,Brand AL YAMUNA DENSONS

  • Brand:
    AL YAMUNA DENSONS
  • Kit Code:
    XSOS - 34
  • Standard:
    IEC-60502-4, IS-13573
  • Cable Size:
    1 x 500 - 800 mm2
  • Impulse Voltage Test:
    170 kV
  • AC Withstand Test Voltage:
    86 kV/5 min
Cable Termination
Item Code #8AZ8DT
Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable, 1 x 1000 mm2 , Kit Code XSOS - 35,Standard IEC-60502-4, IS-13573 mm2,Cable Size 1 x 1000 mm2,AC Withstand Test Voltage 86 min,Impulse Voltage Test 170 kV,Brand AL YAMUNA DENSONS

  • Brand:
    AL YAMUNA DENSONS
  • Kit Code:
    XSOS - 35
  • Standard:
    IEC-60502-4, IS-13573
  • Cable Size:
    1 x 1000 mm2
  • Impulse Voltage Test:
    170 kV
  • AC Withstand Test Voltage:
    86 kV/5 min
Additional Information

Features

  • Heat Shrink Outdoor Termination 33 kV For 1 Core XLPE Insulated Cable
  • All key inputs are produced in-house
  • Corrosion resistant and unlimited shelf life
  • In compliance with IEC-60502-4 / IS-13573
  • Electrolytic grade connectors

Ratings & Reviews

Be the first to write a review
Write a review

Company Information

Name
Al Yamuna Densons FZE
About Us
Ensuring Uninterrupted Power Supply Al Yamuna Densons, a subsidiary of Yamuna Densons India, has been in electrical infrastructure industry for over 45 years. With our plant in the UAE, we've been able to manufacture, distribute our products faster in MENA region. As the MENA region's requirements grow by the day, it's important that Al Yamuna Densons has a presence in the Middle East. Having an already large client base in the UAE, we're happy to be close to our clients to fully service all of their needs.
Information on technical characteristics, the delivery set, the country of manufacture and the appearance of the goods is for reference only and is based on the latest information available at the time of publication.
Similar Products (43)

Loading